At Stella Floorcoverings, we understand that the long term performance of our products depends on a number of contributing factors. The final floor finish is only one of those factors. A good preparation is essential for a smooth installation. All Stella Floorcoverings products can be installed on concrete, timber, ceramic and many other subfloors which have been suitably prepared. The effective application is dependent on suitable site conditions, correct subfloor preparation and dryness, the workmanship of the installer, how the product is maintained and the selection of the correct floorcovering are all equally important. Stella Flooringcoverings aim is to provide proactive information on to architects, specifiers, contractors and consumers to ensure the optimum performance of all Stella Floorcoverings products. If you have any queries regarding product selection, specification, installation, performance or maintenance of any Stella Floorcoverings products, then do not hesitate to contact us. Our aim is to resolve problems prior to the installation of our products rather than have problems to resolve after they are installed.
The current Australian Standards AS/NZS 2455.2:2019 provides detailed commentary on the recommendations for the installation of Carpet Tiles on both new and existing floor surfaces. Stella Floorcoverings consider AS/NZS 2455.2:2019 to be best minimum industry standard for the installation of all carpet tiles and is fully endorsed by Stella Floorcoverings. This technical manual is intended as a guide to all parties involved in the specification, installation and maintenance of Stella Floorcoverings Carpet Tiles.
Stella Floorcoverings always recommends the use of reputable flooring contractors, whose experience in installation and project management will prove invaluable at all stages of a project. Selecting a flooring contractor solely on price can lead to a poor installation and a discontented consumer. A successful installation not only depends on the skills of the floor layer, but also in the planning and management of the project prior and during installation. Open lines of communication between all parties concerned will eradicate any problems and will ensure a successful installation, which meets the design requirements within the allotted time scale. Carpet Tiles are incredibly versatile materials, which comes with a long list of benefits such performance-to-cost ratio, life cycle maintenance costs, Greentag certification, product stewardship, low VOC’s, fire resistance, dimensional stability and that it can be recycled. Selection of the most suitable floorcovering is of utmost importance. Not only must the floorcovering meet the designer’s initial colour and design, but the performance criteria of the product must be sustainable for the anticipated life of the product, allowing for foreseeable actions such as general wear and tear and regular maintenance. Consideration at the initial specification stage must be given to the occupational usage of the building and the building type. Particular attention must be paid to the type and density of traffic (both pedestrian and wheeled), any special acoustical, electrical resistance or slip resistance requirements, as well as reaction to chemicals and staining agents, and physical properties such as resistance to point and rolling loads. Colour selection is also critical to the longevity of the installation, light colours will always show more dirt and stains than darker patterned tiles. If you have any concerns regarding the suitability of your selected product please contact Stella floorcoverings. Our Sales Team and After Sales Department can provide advice on the suitability, performance and application of any of the Stella Floorcoverings products.
Stella Floorcoverings Carpet Tiles should only be laid on subfloors which do not suffer from rising damp or hydrostatic pressure, and where the moisture level does not exceed that of the levelling compounds and adhesives that are being used when tested in accordance with ASTM F2170
Relative humidity in-situ probe test carried out as per ASTM F2170 is the only method of testing acceptable to Stella Floorcoverings. Subfloors with a relative humidity and surface pH exceeding that of the below chart for PVC backed products, and or any proprietary materials being used will invariably cause failure of the bond between the substrate and floorcovering.
To prevent these situations from arising, Stella Floorcoverings does not condone the practice of installing Carpet Tiles on subfloors with a moisture content that exceeds the limitations of the levelling compounds and adhesives being used and accepts no responsibility for non-performance of Stella Floorcoverings products in such instances.
Maximum allowable RH & pH test results
RH Content 75% & Surface pH 7-9.
Stella Floorcoverings does not recommend the use of penetrative moisture barrier systems that cannot be tested for application or performance, or do not have the ability to contain high surface pH. Stella Floorcoverings only recommends the use of topical moisture and pH barrier systems, such as epoxy and polyurethane.For RH and pH test results that exceed the above chart please contact Stella Floorcoverings for further technical advice.
Please note: If the subfloor moisture content falls outside of these parameters please contact Stella Floorcoverings for further instructions before commencing the installation. Stella Floorcoverings will not be responsible for any moisture related installation failures if these guidelines are not strictly followed.
The most common cause of failure in these types of substrate is moisture, either as construction moisture that has not had sufficient time to evaporate, or the absence of an effective vapour barrier used in ‘on ground’ construction.
Concrete substrate moisture is a significant problem which can be either temporary, caused by the original construction procedures, or can be a continuing problem, caused by ground moisture traveling up through the slab on grade. In new construction the excess water in the concrete needs time and conditions which allow it to dry out before installing floor coverings. Placement methods and curing compounds of the concrete will have a big effect of the moisture evaporation rate, not to be confused curing rate of the concrete surface. Ambient temperature, humidity and the environment are also contributing factors in the drying time of concrete. Prior to laying any Stella Floorcoverings Carpet Tiles, it is essential that all free water, which can affect adhesion, be allowed to evaporate from the base or be treated with a moisture mitigation system. Please contact Stella Floorcoverings for further advice in this situation.
Existing concrete and as described in BCA, if laid directly to ground, must contain an effective DPM (Damp Proof Membrane). If one is not present or is suspect, a suitable surface DPM should be applied. A DPM, as the name suggests, is typically a water proof barrier in the form of a thick plastic sheeting designed to prevent the passage of moisture through it. These are normally used beneath a foundation concrete slab. The BCA introduced the compulsory use of DPM’s in the mid 70’s. It is recommended to treat all “on ground” concrete sub-floors prior to this time as they do not have an effective DPM. Preparatory works should be carried out in accordance with proprietary materials that are being used. In some instances, a cementicious smoothing compound of at least 3mm thickness should be applied prior to the installation of the Carpet Tiles. The smoothing underlayment supplier will provide details on which product within their range must be used to suit the end use application and subfloor construction, together with details of which primer should be used.
A power trowel (also known as a “power float”, “helicopter”, “trowel machine” or “whirlybird”) is a piece of light construction equipment used by construction companies and contractors, to apply a smooth finish to concrete slabs. Concrete substrates that are “over worked” with a power trowel can create a crust on the surface of the concrete that slows the drying time of the concrete and creates a smooth dense surface that is difficult to bond to, due to the impervious nature of the surface. It is recommended that highly burnished concrete surface are mechanically prepared with the use of a concrete grinder or shot blasted to remove the top surface and then refinished.
Surface hardeners or curing agents should not be used with power floated concrete, as these can impair the adhesion of the floorcovering and should be mechanically removed as per AS1884:2021 section 3.1.5
Stella Floorcoverings does not recommend the use of penetrative moisture barrier systems that cannot be tested for application or performance, or do not have the ability to contain high surface pH. Stella Floorcoverings only recommends the use of topical moisture and pH barrier systems, such as epoxy and polyurethane.
The finished appearance of a floor covering will only be as good as the quality of the base over which it is installed. Any irregularities in the sub-floor will show through the finished floor. Careful sub-floor preparation is vital for an excellent floor appearance and good installation. The sub-floor must be hard, flat, smooth, clean, dry, free from defects and contaminants, and fit for purpose.
A suitable levelling compound can be used to ensure that no irregularities show through to the surface of the finished floor. However, the selection of suitable materials, including smoothing and levelling compounds and any ancillary products is dependent upon the end use of the completed flooring, and must be agreed by the supplier of the preparative materials and the flooring contractor. Any proprietary materials used for floor preparation must be used in accordance with the manufacturers’ recommended instructions. In all cases, the sub-floor must be sufficiently dry and the relative humidity (RH) checked to ensure it is not greater than that of any proprietary materials that are being used when tested in accordance with ASTM F2170.
New timber suspended floors should be constructed of either tongue and groove, plywood or chipboard specifically manufactured for flooring. Spacing of the supportive joists should be in accordance with the manufacturer’s recommendations in relation to the board’s thickness and the BCA. When underlayment panels are used, they must be underlayment grade as specified and warranted by the manufacturer. Underlayment panels and joints must be fastened and reinforced according to manufacturer’s instructions. Completely sand the floor with a floor sander, so that the floor is smooth and flat before installing underlayment panels. Without sanding properly, timber substrates can have high and low spots throughout the floor that could telegraph through the carpet tiles. Stella Floorcoverings
recommends the use of an underlay or underlayment on all timber substrates, to ensure stability and uniformity Any failure of the underlayment or flooring due to the underlayment is NOT the responsibility of Stella Floorcoverings. All timber substrates must have a minimum earth clearance of 400mm in accordance with the BCA and have well ventilated air space beneath it.
Where existing timber, plywood or particleboard subfloors are to be used as a substrate worn, rough, cupped or warped surfaces shall be sanded or filled, but must retain structural adequacy. In some circumstances, it may be necessary to re-nail the old floor or to repair it by replacing the worn and unsound sections without good ventilation, the application of an impervious floorcovering could lead to dry rot in the structure beneath. Most smoothing compounds are unsuitable for applying to timber bases due to the movement of the base. Seek advice from the smoothing underlayment manufacturer for the correct grade of product for your specific application.
Stella Floorcoverings carpet tiles may be installed over other hard floors. Any surface contaminants must be removed prior to installation of new carpet tiles. All other existing floorcoverings such as existing carpet, underlay, loose laid vinyl, cushion back vinyl and existing adhesives must be uplifted and completely removed. Existing adhesives must be mechanically removed.
The floor must be sound and firmly fixed and any loose or powdery material removed from the joints. The surface should be prepared with a light grind to remove any surface contaminants and any cracks cleaned out and filled with a suitable resin bonded cement/sand mixture. In most instances, a cementitious smoothing or levelling compound of at least 3mm thickness must then be applied to provide surface porosity for acrylic adhesives prior to the installation of the vinyl floorcovering.
Sand/cement screed bases are not a suitable substrate for the installation of floor coverings and a suitable levelling compound should be applied.
Before installing over ceramic or quarry tiles, ensure the floor is in good condition before you can begin installing carpet tiles. Check for loose, cracked or broken areas of ceramic tile. These areas will need to be removed with a hammer and chisel and thoroughly cleaned of all debris. The floor must be sound and firmly fixed and any loose or powdery material removed from the joints. The surface should be prepared with a light grind to remove any surface contaminants and any cracks cleaned out and filled with a suitable resin bonded cement/sand mixture. In most instances, a cementitious smoothing or levelling compound of at least 3mm thickness must then be applied to provide surface porosity for acrylic adhesives prior to the installation of the resilient floorcovering.
Information of the best method to prepare a ceramic or quarry tile floor should be sort from primer and levelling compound manufacturer.
Metal bases are generally, but not exclusively, steel and can be contaminated with rust or oxidisation, oil and grease. The surface should be thoroughly degreased and then abraded or wire brushed to remove the rust or oxidisation. Any high spots may need to be ground off. In most instances, but not where there is excessive vertical or lateral flexing or movement, a cementicious smoothing compound of at least 3mm thickness must then be applied prior to the installation of the carpet tiles.
On access floors, the edge of the tile must not line up with joins in the access panels. The edge of the tile must be sufficiently far enough away from, the access panels joins that it will not be effected by lateral movement. Before installing over painted or epoxy floors, ensure the floor is in good condition before you can begin installing carpet tiles. Check for loose, cracked or broken areas of the surface. These areas will need to be removed mechanically and thoroughly cleaned of all debris. The floor must be sound and firmly fixed and any loose or powdery material. The surface should be prepared with a light grind to remove any surface contaminants and any cracks cleaned out and filled with a suitable resin bonded cement/sand mixture.
Filling the expansion joint with sealant which is not specifically designed for expansion joint filling or floor smoothing underlayment will lead to floor failure and is not recommended by Stella Floorcoverings.
In many of the areas where Stella Floorcoverings carpet tiles are installed, other types of floorcovering will also be used. The junction between the Stella Floorcoverings flooring and these other types of floorcovering is a potential weak point, if not treated properly. Correct installation minimises problems such as trip hazards and damage to carpet. The use of proprietary patching and levelling compounds is recommend to make the transition between floor surfaces smooth and gradual.
In installations where the carpet tiles join with ceramic tiles or the like, it is important that a smooth transition is achieved at the junction. Aluminium edge trims are recommended for this purpose. They enable a flush cut with the trim, while providing an excellent guide to apply patching and levelling compounds.
It is important that the junction between carpet tiles and broadloom carpet is clearly visible and that any trip hazard is minimised by using edging strips. A variety of edging strips are available for this junction. The relevant manufacturers can supply further advice on installation and use of these types of trims.
Diminishing strips should be used at all exposed edges of Stella Floorcoverings carpet tiles when they are not abutting another flooring material to minimise trip hazards.
The selection of the most appropriate adhesive is generally made by the floor covering manufacturer and specified in the installation instructions.
Pressure Sensitive Adhesives are solvent free and low odour. They are specially formulated for installing PVC backed, fibre backed, and cushion backed carpet tiles. There are many acrylic adhesives on the market. Most are water based, which means that the curing action occurs when the water evaporates into the porous substrate after the adhesive is applied. They can be classified as semi-soft set or pressure sensitive for a semi-permanent installation.
Contact adhesives have a solvent, neoprene or water base and are classed as soft set. The adhesive is applied to both surfaces and allowed to dry before the two surfaces are brought together. When the surfaces contact each other the bond is instant. This makes them suitable for use on vertical surfaces, such as vinyl skirtings and covings. Note that the adhesive is not waterproof, so the exposed edges must be sealed to stop water penetration.
Installation of Cushion back tiles, adhesive should be applied with a V1 notch trowel. Roller application is not permitted.
Ideally all excess adhesive should be removed as work proceeds. Water based adhesive can, before it is dried, be easily removed using a damp cloth. For removal of specialist adhesives follow the manufacturer’s guidelines. Dried adhesives are more difficult to remove and the majority should be removed using a spatula without damaging the flooring. Once this is done, a proprietary cleaning agent, as recommended by the adhesive manufacturer, can be used sparingly. Always test a trial area first in an unnoticeable area, as many of the stronger cleaners contain solvents which can cause staining and softening of the vinyl.
Each module has directional arrows on the backing. This allows for one-directional or multi-directional installation. Please refer to each product specification sheet to determine the allowed method of installation.
NOTE: Lineal patterns when installed directional may produce an undesired effect when lines of the same colour meet on two edges. Installers need to monitor this during installation and reposition tiles where appropriate. Patterns that are random in nature may contain additional colour ways to the ones displayed on the samples. Please consult your commercial sales consultant for further information.
Roll the entire installation with a 35kg roller once it is completed.
Use plywood over the carpet when heavy objects are moved within the next 24 hours after
Due to the concentrated point-load created by the castors of office chairs, it’s mandatory to use under chair floor mats to ensure optimal carpet performance and to ensure ongoing warranty of the tiles. “This is essential on cushion and acoustic backed products”.
This will also prevent excessive wear to the face and possible transfer of the pressure-sensitive adhesive to the back of the carpet.
Never install Triangle Shape with 6 touching points under castor chairs without a chair mat protection.
Stella Floorcoverings carpet tiles can be installed on stairs. It is highly recommended that separate pieces be cut and applied to the step and riser. The junction should be covered with an appropriate nosing, both for aesthetic value and safety. Size of cuts and types of nosing will depend on the style of stairway and type of environment.
The Square and Rectangle are the only 2 shapes allowed for installation over stairs.See below for directions.
Riser – Always ensure that the arrow on the back of the carpet tile is pointing down the riser. The riser of the carpet tile is securely held in position by the stair nosing and adhesive.
Tread – Arrow must run into the step at a right angle. Apply adhesive to the entire tread. Then fit stair nosing.
When selecting the installation method for carpet tiles, consideration must be given to the design and construction of the carpet tiles, as well as the level of foot traffic they will be subjected to. Consideration of the above points will assist in maximizing the performance and appearance retention of carpet tiles. Please contact your local area sales representative to discuss the installation options prior to the installation and always refer to the Product Brochure for recommended installation methods.
NOTE: Each carpet tile has a directional arrow printed on the backing to show the pile direction
SQUARE INSTALLATION SHAPES:
RECTANGLE INSTALLATION SHAPES:
RIGHT-ANGLE INSTALLATION: Adhesive should be applied with a V1 notch trowel. Roller application is not permitted.
SHAPES:
TRIANGLE INSTALLATION: Adhesive should be applied with a V1 notch trowel. Roller application is not permitted.
TRAPEZOID INSTALLATION: Adhesive should be applied with a V1 notch trowel. Roller application is not permitted.
HEXAGON INSTALLATION: Adhesive should be applied with a V1 notch trowel. Roller application is not permitted.
PLANKS: Herringbone 45°
PLANKS:
BRICK BOND PLANKS:
ASHLAR: Line 2 Line 2 Line 1
PLANKS: Basket Weave Line 2 Line 1
The following guide should be reviewed prior to commencement of any cleaning and maintenance on carpet tiles. This guide has been prepared by Stella Floorcoverings technical division to assist you in maintaining and extending the life of your carpet tiles over many years to come.
It includes information on maintenance, the importance of planning, recommended maintenance frequency, reduction of soiling, removal of dry soil, vacuum cleaner recommendations, cleaning, spot and spill removal and general information.
You can protect your investment and extend the life of your carpet with regular maintenance and care.
For further information, please do not hesitate to contact your local area sales consultant or visit Stella Floorcoverings on the web at www.stellafloorcoverings.com.au
There are key factors that will affect the appearance of Stella Floorcoverings carpet tile products after installation such as:
Maintaining the overall appearance of the Stella Floorcoverings carpet tile products requires that:
The following recommendations are to be followed to ensure that the overall appearance of the installation is maintained:
Colour selection will affect the appearance the performance of the carpet tiles, darker colours will maintain their appearance better than lighter colours.
This product must be fully adhered to the subfloor (direct stick method)
By re-arranging furniture periodically, the traffic pattern is changed and allows the carpet tiles to wear more evenly.
Stella Floorcoverings carpet tile products are quality engineered to provide a long useful life and enhance the working environment.
Carpet tile offers many advantages over other flooring systems, such as sound absorption, reduced fatigue and lower maintenance costs. From the start, the maintenance program should be considered as part of the buying decision. If proper maintenance is neglected, the carpet’s appearance and performance will suffer, shortening the carpet’s useful life and raising long-term costs.
A comprehensive carpet care program consists of the following four (4) elements:
Carpet tile maintenance must be established as a scheduled program, rather than being a random series of reactions to soiling conditions and infrequent cleaning. Virtually every complaint of poor appearance, rapid soiling, pile crushing and many times poor performance has been shown to be related to a lack of planning and control for the maintenance program.
The most important consideration when planning a maintenance program is the budget.
Like other expensive furnishings or equipment, advanced static-controlled carpet tiles represent a substantial investment for any facility and deserve adequate care to prolong its effective life. If the carpet tile maintenance budget is set unrealistically low, the carpet tile will need to be replaced prematurely.
Other items to consider are the amount of traffic and type of soiling, which will vary by area.
Due to the higher traffic level, entrance lobbies, and hallways will need more care than offices. Production line areas and outside entrances will require more effort due to the more difficult soiling conditions.
Colour and pattern are critical to ensuring appearance retention.
Recommended maintenance frequency
The use of walk-off mats at transition areas from the outside or hard surface to carpet tiles is important. Walk-off mats can greatly reduce the amount of soil entering a facility by normal traffic. There are two (2) types of mats which should be used:
When both types of mats are used in combination, they should always be placed so that incoming traffic passes over the soil removal mat first, because the absorbent types have very little soil holding ability. For mats to continue to trap soil, they should be cleaned on a regular basis.
Vacuuming is the most significant element in the maintenance of carpet tiles and in the overall appearance of the facility. Research has shown that 85% of the soil tracked into a building is dry, and the other 15% is oily. Vacuums are designed to control this dry soil.
Frequent vacuuming removes particulate soil from the surface before it works down into the pile where it is more difficult to remove. Walking on the carpet accelerates the rate at which the particles settle deep into the pile.
Areas with heavy traffic, such as entrances and major corridors, restaurants and assembly or manufacturing, should be vacuumed at least once a day. Areas with less traffic, such as offices, computer rooms, engineering labs, should be vacuumed every other day depending upon conditions.
Vacuum cleaner recommendations carpet tile care & maintenance
Please see below for the recommended vacuum cleaner types:
Cleaning, even with thorough vacuuming, is necessary to remove the 15% of soil which is the oily type material. In order to maintain a good appearance, carpet tiles must be cleaned on a periodic basis to prevent it becoming so dirty that it can no longer be cleaned satisfactorily.
The frequency of cleaning must be adjusted to the rate at which soil accumulates; therefore, heavy traffic areas typically require more frequent cleaning, as do areas with less traffic but more soil.
When the colours of the carpet tiles begin to look dull, it is time to clean them. The traffic lanes will show this first. If the carpet tiles are cleaned before it becomes excessively soiled, the cleaning will be more successful and a much easier task. This is especially important in places oily soil is prevalent, such as the areas near streets or asphalt parking lots, and those around certain messy electronic manufacturing operations, SMT line and cleaners. Solder and production soil forms a sticky material similar to varnish which traps and holds dry soil and may become nearly impossible to remove as it ages.
NOTE: Damp carpet tiles clean shoes and collect soil faster. The resulting black discoloration in the traffic lanes will require pre-treatment with a traffic lane cleaner to break down the soiling. It also requires the use of hot, not warm, water to effectively clean the carpet tiles.
When choosing a proper cleaning system, it is necessary to consider how effectively it cleans and how well it enhances the appearance retention of the carpet tile texture without leaving a heavy residue.
Stella Floorcoverings recommends the hot water extraction system, which research indicates provides the best capability for cleaning. This system is commonly referred to as “steam cleaning” although no steam is actually generated. The process consists of spraying a solution of water and cleaning agent into the pile and using, a powerful vacuum, recovering the used solution and soil into a holding tank. This can be best done from a truck-mounted unit outside the facility with only the hose and wand brought into the facility.
It is important to deliver clean water at a minimum of 93°C to the carpet tile face. Self-contained, walk-behind machines are another type of hot water extraction equipment commonly used. They apply the cleaning solution at a rate which is balanced with the recovery capability of the machine, resulting in a carpet that is only damp after cleaning.
This feature prevents untrained users from over-wetting the carpet to the point that drying time is unacceptable. This type of machine is employed largely by hospitals and schools with in-house maintenance staff. One variation of this equipment continuously recycles the cleaning solution for multiple uses. Stella Floorcoverings does not
recommend the use of this equipment because as the recycled solution is reused, the materials dissolved in it are distributed over the entire area.
Stella Floorcoverings recommends the use of a company which is a member of a professional association.
Recommendations for in-house maintenance
If you decide that cleaning by in-house personnel is best, here are some guidelines to follow:
All maintenance procedures mentioned thus far have been planned; spot and stain removal is the reaction to an unplanned incident. Therefore, it is desirable to have the needed materials handy by planning ahead of time. Professional carpet cleaning companies have spot removal kits available in convenient carrying cases that contain all the necessary materials.
Remove as much of food spills as possible by scraping gently with a spoon or dull knife. Absorb wet spills as quickly as possible by blotting with white paper or cloth towels. Always blot, never scrub or rub abrasively, as a fuzzy area may result. When blotting, work from the outer edge in toward the centre of the spot to avoid spreading the spill and enlarging the problem. Always follow spot removal with a water rinse to remove the sticky residue from the spotter; the residue can cause rapid re-soiling. There are spotting extractors that work well for the rinse-and-extract method. Always draw out the remaining moisture with several layers of white towels weighted down on the spot.
The over dilution of detergent, and or failure to properly rinse detergent solution from the carpet tiles has the propensity to increase the stains appearance. Be sure to thoroughly rinse detergent from carpet tiles.
*Stella Floorcoverings reserves the right to update this document at any time and without prior notice. This document is current at the time of printing.
For the latest version please refer to our website www.stellafloorcoverings.com.au